Towerstat rf user instructions

Tn9 1tb telephone 01732 359888 telefax 01732 354445. Neutral honeywell and danfoss etc are different so you will need to check the wiring diagram included with the new one you purchase. It uses the rf radio frequency technology, allows you to control your room temperature from anywhere inside your house. Press manual button to revert the three modes in turn. Towerstat sttrsfn frost protection thermostat rm distribution. If its too cold, the thermostat will tell the heating to come on and when the home is back up to temperature it will turn your heating off. Push p to bring up programme 1, this is the first on time monfri. The thermostat seems to be sending the signal brand new duracell batteries, but the receiver is not having it. From reading the manual i posted i am expecting a permament red light, and a green light only when heating is actively on. I have just moved to a house that has instaled a towerstat. Press the button on the control centre until the set temperature is higher than room temperature by a. First and foremost it is an excellent programmable thermostat with a builtin 5 amp rated relay. Testing the rf transmission override the setting temperature 1.

In addition it can be used as a simple and affordable programmable timer for use with low voltage battery powered applications. Setting the clock 1, press reset 2, press clock button 3, set the day using the up or down arrow buttons 1 monday 4, press clock button 5, set hours using the up or down arrow buttons 6, press clock button 7, set the minutes with the up or down arrow buttons 8, press the clock button. I have a towerstat rf thermostat controlling my central heating about. We have a range of heating controls and boiler accessories to help you install hasslefree, energy efficient and cost effective heating systems for your customers while meeting all the legislative requirements. Can i replace my towerstat rs thermostat with any new one. Feb 08, 2011 i have an rf towerstat which was installed 3 yrs ago and has been problem free until now. Can i use my towerstat rf to switch the heating onoff. The towerstat rf bm consists of a freestanding batterypowered 2 x aa alkaline radio frequency transmitter tx, and a boiler module, which is a boilermounted modular receiver rx. The device can be linked to heating or cooling components. When in override, the new set higher than room temperature by a few degrees. Digital programmable thermostat for weekdayweekend setting this is the instruction manual for the towerstat rsp please click on one of the above sections to view the manual. Salus t105 rf instruction manual pdf download manualslib. Me again, new house all of that and i need a user manual.

When auto is selected, the timer operates as the programs. Nov 16, 2011 i have just moved to a house that has instaled a towerstat rf model sttrftx and have no idea how top use controls can answered by a verified plumber we use cookies to give you the best possible experience on our website. The sttrsn volt free room thermostat is from tower tfc group. New to find out how to modify this thermostat so that it can be. Instruction manual towerstat rf selectable volt free warning please read this manual prior to installation or use shock hazard this unit must be installed. With mains power connected to the receiver, press the button on the side of the receiver module. Sttrsn tower tfc group towerstat room thermostat by electramania. I have a towerstat rf thermostat with a receiver that activates a baxi combi boiler. I have a towerstat rf thermostat controlling my central heating about a year old.

In the normal operation mode, the current set range temperature can be overriden by pressing the up 1. Room stat, towerstat rs, 535 deg c spst tn1010 in domestic heating controls grasslin. This double unit thermostat is linked by radio frequency. Floureon remote control wireless rf plug in thermostat. Ive changed the batteries and the heating still runs, no matter. Worcester greenstar cdi and towerstat rf been on holiday. I need a copy of the spec sheetcan it be emailed to me also thank you so much.

Tfc group sttrf user manual 19 pages manuals directory. Towerstat receiver and transmitter both look fine but boiler not firing up. Page 1 user manual wall hung rsf gas fired condensing system boiler greenstar i system for central heating systems ukie. Boiler appears fine, firing up for hot water etc when required. However, although thermostat receiver and transmitter appear fine everything lit up.

Tower rf wireless programmable room thermostat rfwrt for. Oct 04, 2010 i have a baxi boiler and a towerstat rf controller, i changed the batteries in the controller and now my boiler is on answered by a verified hvac technician we use cookies to give you the best possible experience on our website. Sep 17, 2009 me again, new house all of that and i need a user manual for the thermostat control on my gas central heating. The sttrfsn has volt free changeover contacts for use in cooling or heating applications. Mar 26, 2014 mquad, are you happy with the location of your current stat. I imagine it was the capacitive dropper he was wise to use the smaller value but it was unnessasary to. Jan 10, 2014 how do i operate towerstat rsp central heating thermostat controller. This is the instruction manual for the towerstat rsp please click on one of the above sections to view the manual. Towerstat radio frequency thermostat garden of eden. Press the button on the control centre until the set temperature is higher than room temperature by a few degrees.

Press p button select day or days by pressing up arrow button repeatedly until your day selection is visible. Towerstat receiver and transmitter both look fine but. The advantage is that the user can keep the transmitter nearby and can read control the temperature of the living area in immediate use. Worcester greenstar i system user manual pdf download. I have tried new batteries in the wireless thermostat, different frequencies for the. Does anybody have any experience in installing a towerstat rf. To change the address code of the transmitter, open the transmitter housing refer to battery replacement section to open housing. However on following the the instructions for turning on the centra heating i get nothing. Hi i have a towerstat rf fitted on a heatline boiler. Relay status is only changed in normal mode display elements. I recently pressed the reset button to clear all the progrrams and since then it has failed to function properly. If you want to change any of these settings you can do so by following the instructions on page 8. Press the inset button between the down temp and p buttons set the time using the m min, h hour and d day buttons press p to get into programming mode, one press gives program setting 1, 2 presses program 2 etc, you have 6 programs.

Simple tower stat settings westpoint underfloor heating. Grasslin uk ltd tower house vale rise, tonbridge kent. Nov 05, 20 i have a pdf instruction manual for a towerstat rf, sttrf. Towerstat receiver and transmitter both look fine but boiler. I turned o the boiler as per the instructions turned on hot water setting,turned u temp on that, turned on hot tap and voila. This is a high quality batterypowered programmable timer thermostat which has many uses. Worcester greenstar cdi and towerstat rf been on holiday mode and when switched back on, battery symbol on towerstat answered by a verified plumber we use cookies to give you the best possible experience on our website. Including drayton thermostats, honeywell thermostats, salus thermostats, smart thermostats, wireless thermostats, room thermostats, digital thermostats, wireless central heating thermostats. I have problem with my ch whereby first thing in the morning when the heating comes on it. Read the instructions, it may have lost its pairing. To check the rf reception, follow the following steps. If this looks like your controller and you can provide me a email address i will be happy to email you the pdf manual. Do you have the installation user instructions for the towerstat.

Next, bring up programme 2 by pressing p twice, this is the first off period for monfri, this. Sorry, its a baxi duo tec boiler and a towerstat rf. From reading the manual i posted i am expecting a permament red light, and a green light only. I have a baxi boiler and a towerstat rf controller, i changed.

Worcester greenstar cdi and towerstat rf been on holiday mode and when switched back on, battery symbol on towerstat answered by a verified plumber. I dont have any info in the rsp verison, however i did find the following programming instructions. Do you have the installationuser instructions for the towerstat. The towerstat rfbm consists of a freestanding batterypowered 2 x aa alkaline. I have a remeha avanta plus boiler and a towerstat rf wireless thermostat thingy.

Remove one or more of the jumper links as shown in the illustration below. Towerstat rf selectable volt free pdf free download. These instructions apply in the ukie only and must be followed. The volt free thermostat is designed to provide automatic onoff control for gas valves, circulation pumps, relays and zone valves in all heating, cooling, or heatingcooling installations. Programmable rf thermostat type rfwrt introduction this thermostat can replace any standard room thermostat, and is designed for use with gas or oil heating systems. Nov 15, 20 here is a spec sheet for a towerstat rf with the programming instructions on it. Room thermostats work by sensing the air temperature in the home and communicates with your heating system. Towerstat rf, selectable volt free read online or download pdf tfc group sttrf user manual. How do i wire the receiver to my boiler for 230 volts. Send relay onoff command for refreshing relay every 1 minute 4. However, although thermostat receiver and transmitter appear fine everything lit up etc, it doesnt actually fire up the central heating. If you want to set your own programme follow these instructions. Here is a spec sheet for a towerstat rf with the programming instructions on it.

For any other details refer to operating instructions and wiring details provided with each thermostat. Me again, new house all of that and i need a user manual for. The manual 19 pages, however, this site will not allow a pdf upload. Unit one is the receiver and unit two is the controller. The boiler module rx is mains powered by connecting to existing wiring within the boiler, and controls a voltfree changeover switch according to signals from. I have noticed recently that the central heating has stopped working, the hot water works fine.

The batteries ran low on the transmitter yesterday and ever since, the heating has been on non stop. Worcester greenstar cdi and towerstat rf been on holiday mode. Page 1 user manual wall hung rsf gas fired condensing system boiler greenstar i system for central heating systems ukie page 2 preface preface please read these instructions carefully these instructions are applicable to the worcester, bosch group boiler model stated on the front cover only. I am attaching a jpeg of the specifications which is one page for you to look at.

I have a pdf instruction manual for a towerstat rf, sttrf. If you wish to control electric heating note that the current rating of the receiver is 3a resistive. The sontay rf rx20 or rf rx40 receiver collects data from all other devices on the radio network, including measurements from sensors, link quality for all links formed in the network, battery levels for all battery powered devices, hours run for all devices and the current status of all devices. Feb 07, 2015 hi, hoping i can get some advice on here.

I have just moved to a house that has instaled a towerstat rf. You have live, neutral, com and no on the receiver. I really just need to find a set of instructions online. The manual specifies it has three connections, live, neutral and. So, as i said, it appears the termostat receiver has failed. Suitable for many kinds of heating device and protect some home appliances. Transmitter serves as the user interface and for temperature. Depending on what these three wires are is it 3 in total, or 3 plus an earth. Transmitter serves as the user interface and for temperature sensing control.

Page 2 preface preface please read these instructions carefully these instructions are applicable to the worcester, bosch group boiler model stated on the front cover only. It features several user overrides including frost protection, thermostat mode and time or temperature display. It will automatically turn onoff heating device as the ambient temperature changing, in order to maintain a constant room temperature. Please tell me how to adjust a drayton digistat rf1.

904 808 325 730 1567 1174 1132 1025 719 74 221 968 799 1535 576 1094 1609 422 841 1672 770 1231 396 490 734 1418 197 414 752 516 724 722 1134 688